Thermal Conductivity and Diffusivity of Inconel 600
Thermal Conductivity of Inconel 600 at Elevated Temperatures
Temp. °F | 70 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 |
TC | 8.6 | 8.7 | 8.9 | 9.1 | 9.3 | 9.6 | 9.8 | 10.1 | 10.3 | 10.6 |
Temp. °F | 550 | 600 | 650 | 700 | 750 | 800 | 850 | 900 | 950 | 1000 |
TC | 10.8 | 11.1 | 11.3 | 11.6 | 11.8 | 12.1 | 12.4 | 12.6 | 12.9 | 13.2 |
Temp. °F | 1050 | 1100 | 1150 | 1200 | 1250 | 1300 | 1350 | 1400 | 1450 | 1500 |
TC | 13.4 | 13.7 | 14.0 | 14.3 | 14.6 | 14.9 | 15.2 | 15.5 | 15.8 | 16.0 |
Thermal Diffusivity of Inconel 600 at Elevated Temperatures
Temp. °F | 70 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | 500 |
TD | 0.154 | 0.154 | 0.155 | 0.156 | 0.158 | 0.160 | 0.163 | 0.165 | 0.168 | 0.170 |
Temp. °F | 550 | 600 | 650 | 700 | 750 | 800 | 850 | 900 | 950 | 1000 |
TD | 0.172 | 0.175 | 0.177 | 0.179 | 0.181 | 0.183 | 0.184 | 0.186 | 0.188 | 0.189 |
Temp. °F | 1050 | 1100 | 1150 | 1200 | 1250 | 1300 | 1350 | 1400 | 1450 | 1500 |
TD | 0.191 | 0.192 | 0.194 | 0.196 | 0.197 | 0.199 | 0.201 | 0.204 | 0.206 | 0.208 |
All values are in conformance with ASME BPVC Section II Part D physical properties of UNS N06600.
CATEGORY AND TAGS: