Tel: +86-0311-89642206 | Email: sales@metalspiping.com

Thermal Conductivity and Diffusivity of Inconel 600

Thermal Conductivity of Inconel 600 at Elevated Temperatures

Temp. °F70100150200250300350400450500
TC8.68.78.99.19.39.69.810.110.310.6
Temp. °F5506006507007508008509009501000
TC10.811.111.311.611.812.112.412.612.913.2
Temp. °F1050110011501200125013001350140014501500
TC13.413.714.014.314.614.915.215.515.816.0
*TC: the coefficient of thermal conductivity, unit: Btu / hr-ft-°F.

Thermal Diffusivity of Inconel 600 at Elevated Temperatures

Temp. °F70100150200250300350400450500
TD0.1540.1540.1550.1560.1580.1600.1630.1650.1680.170
Temp. °F5506006507007508008509009501000
TD0.1720.1750.1770.1790.1810.1830.1840.1860.1880.189
Temp. °F1050110011501200125013001350140014501500
TD0.1910.1920.1940.1960.1970.1990.2010.2040.2060.208
*TD: the coefficient of thermal diffusivity, unit: ft2 / hr.

All values are in conformance with ASME BPVC Section II Part D physical properties of UNS N06600.