Thermal Conductivity and Thermal Diffusivity for Alloy 625

TC is the thermal conductivity with an unit of Btu/hr-ft-°F, and TD is the thermal diffusivity with and unit of ft2/hr. The nominal coefficients of TC and TD for nickel alloy 625 (UNS N06625) at elevated temperatures are listed in below two tables. Note that ±10% uncertainty may exist due to compositional variations and analytic data deviation.

 Coefficients of TC & TD for Alloy 625 @ (70°F~750°F)

Temp.TCTD
705.70.110
1005.80.113
1506.00.116
2006.30.119
2506.50.121
3006.70.124
3507.00.126
4007.20.128
4507.50.130
5007.70.132
5507.90.134
6008.20.136
6508.40.138
7008.70.140
7508.90.142
*Temp.: indicated temperature, °F.

 Coefficients of TC & TD for Alloy 625 @ (800°F~1550°F)

Temp.TCTD
8009.10.144
8509.40.146
9009.60.148
9509.80.150
100010.10.152
105010.30.154
110010.50.156
115010.80.158
120011.00.159
125011.30.161
130011.50.163
135011.80.165
140012.00.167
145012.30.169
150012.60.172
1550-0.175
*Temp.: indicated temperature, °F.